HOW TO ENTER SERVICE MODE TO PHILIPS [21PV385 /01 /07 /39 / 58]
The optical sensor system are used for tape start and end sensor on this equipment.
TO ENTER SERVICE MODE
- Cover start sensor [Q202], and end sensor [Q201] with insulation
tape or enter service mode to activate Sensor Inhibitation automaticlly. - Turn ON the Power with Main Power on the front panel of the unit.
- Press [Standby/On],2,7,1 & Mute buttons on the remote control
unit in that order, within Five seconds. When entering service mode "4"
will appear display at corners of the screen. - During service mode, electrical adjustment mode can be selected by remote control key.
- Menu Key => Picture adjustment mode.
- Volume Dn key => SECAM black level adjustment mode.
- [0] key => C-Trap adjustment mode.
- [1] key => DSPC adjustment mode.
- ]2] key => H adjustment mode.
- [3] key => Head switching point adjustment [Auto adjustment]
- [4] key => auto record mode.
- [5] key => head switchin point adjusment [manual adjustment]
- [6]&[7] keys not used.
- [8] key => H-Shift adjustment mode.
- [9] key => V size/V shift adjustment.
The deck mechanism assembly is mounted on the main CBA directly and
SW211 (record saefty switch]) is mounted on the main CBA. When deck
mechanism assembly is removed, from the main CBA due ot servicing this
swich cannot be operated properly.
- To eject tape, press the Stop/Eject button on the unit.
- When you want to record during service mode, press the record button, while depressing [SW211] on the main CBA.